Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Turk J Anaesthesiol Reanim ; 50(4): 309-311, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35979980

RESUMO

Serotonin syndrome, malignant hyperthermia, and neuroleptic malignant syndrome are life-threatening conditions with similar clinical presentations, all of which may occur in post-operative patients. The rarity of these conditions has limited their research as well as the ability to recognise and treat them effectively. We present the case of a 61-year-old male who developed altered mental status, respiratory distress, fever, and haemodynamic instability following post-operative administration of tramadol and meperidine. The differential diagnosis process and process of elimination were used to diagnose this patient with serotonin syndrome. Chart review was used to review the details of the case to write this report. Serotonin syndrome was eventually diagnosed in the context of the symptoms following the administration of 2 serotonergic agents. The patient's symptoms improved with supportive care and did not recur. This case is one of the first published reports of serotonin syndrome resulting from an interaction between tramadol and meperidine, highlighting the importance of constant vigilance in the perioperative period when serotonergic agents are involved. The increased usage of serotonergic antidepressants and Enhanced Recovery After Surgery protocols calling for serotonergic analgesics represent a significant and underrecognised potential for serotonergic multidrug interactions to occur.

2.
Interv Neuroradiol ; : 15910199221104616, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35648585

RESUMO

INTRODUCTION: As we emerge from the current pandemic, hospitals, staff, and resources will need to continue to adjust to meet ongoing healthcare demands. Lessons learned during past shortages can be used to optimize peri-procedural protocols to safely improve the utilization of hospital resources. METHODS: Retrospective review of patients who underwent elective endovascular intracranial aneurysm treatment was performed. Multivariable logistic regression was used to identify factors associated with patients who were able to be discharged within 24 h of elective procedures. Rates of complications (particularly readmission) were determined. RESULTS: 330 patients underwent elective endovascular aneurysm treatment with 86 (26.1%) discharged within 24 h. Factors associated with earlier discharge included procedure years (2019-2021) and male sex. Patients were more likely to be discharged later (after 24 h) if they underwent stent-coil embolization or flow-diversion. There was no association between discharge timing and likelihood of readmission. DISCUSSION: Our review highlights the safety of earlier discharge and allowed us to prepare a fast-track protocol for same-day discharge in these patients. This protocol will be studied prospectively in the next phase of this study. As we gain more comfort with emerging, minimally invasive endovascular therapies, we hope to safely achieve same-day discharge on a protocolized and routine basis, reducing the demand of elective aneurysm treatments on our healthcare system. CONCLUSION: We retrospectively demonstrate that early discharge following elective aneurysm treatment is safe in our cohort and provide a fast-track pathway based on these findings for other centers developing similar protocols.

3.
J Cardiothorac Vasc Anesth ; 36(11): 3990-3998, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35545458

RESUMO

Aortic valve repair (AVr) aims to preserve the native aortic leaflets and restore normal valve function. In doing so, AVr is a more technically challenging approach than traditional aortic valve replacement. Some of the complexity of repair techniques can be attributed to the unique structure of the functional aortic annulus (FAA), which, unlike the well-defined mitral annulus, is comprised of virtual and functional components. Though stabilizing the ventriculo-aortic junction (VAJ), a component of the FAA, is considered beneficial for patients with chronic aortic insufficiency (AI), the ideal AVr technique remains a subject of much debate. The existing AVr techniques do not completely stabilize the VAJ which may increase susceptibility to recurrent AI due to VAJ dilation. An emerging new technique showing promise for the treatment of both isolated and complex AI is AVr using HAART 300TM geometric annuloplasty ring (GAR). The GAR is implanted below the valve leaflets in the left ventricular outflow tract (LVOT), providing stability and creating a neo-annulus. As with other AVr subtypes, this procedure has a learning curve. There are unique surgical and echocardiographic aspects of AVr with GAR, including the appearance of the LVOT, the aortic valve leaflets, and their motion which cardiac anesthesiologists and echocardiographers must be familiar with. In this work, using an eight-patient echocardiographic case series, we provide an overview of this novel AVr technique, including some unique aspects of device sizing, patient selection, expected post-repair echocardiographic features, and a review of outcomes data.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Terapia Antirretroviral de Alta Atividade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia , Humanos , Resultado do Tratamento
4.
J Cardiothorac Vasc Anesth ; 36(5): 1268-1275, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35031222

RESUMO

OBJECTIVE: The study authors sought to compare outcomes in patients with severe mitral valve regurgitation (MR) undergoing urgent, as compared to elective, mitral valve repair employing MitraClip. They hypothesized that, compared to elective cases, MitraClip procedures performed for urgent indications would be associated with increased intraoperative and postoperative complications but have similar long-term outcomes. DESIGN: A retrospective chart review with 3:1 propensity score matching of elective-to-urgent cases. SETTING: A single, large-volume tertiary care academic medical center. PARTICIPANTS: All consecutive patients with severe MR who underwent elective or urgent MitraClip procedures between December 15, 2015, and October 26, 2020. INTERVENTIONS: MR repair with MitraClip. MEASUREMENTS AND MAIN RESULTS: As expected, patients in the urgent MitraClip group required a higher level of preprocedural care, and there were significant differences in baseline demographic and clinical variables as compared to the elective group. To reduce baseline characteristics heterogeneity, propensity matching was performed for age, left ventricular systolic dysfunction, congestive heart failure, chronic obstructive pulmonary disease, and smoking histories, using the nearest-neighbor matching with a caliper of 0.2 and with replacement. The final study cohort included 89 urgent and 252 matched elective cases, with a suitable alignment between the treatment groups. Propensity-matched urgent MitraClip patients experienced a longer hospital length of stay (p < 0.001), increased intensive care unit admissions (19% v 4%, p < 0.001) and mechanical ventilation (6.7% v 1.6%, p = 0.023), postprocedural atrial fibrillation (11% v 4.4%, p = 0.036), pericardial effusion (10% v 2.4%, p = 0.005), and acute kidney injury (7.9% v 2%, p = 0.016). Furthermore, patients in the urgent cohort incurred significantly higher 30-day cardiovascular mortality (6.7% v 2%, p = 0.039), increased 30-day (16% v 5.6%, p = 0.006), and 1-year (33% v 20%, p = 0.021) readmission rates. However, there were no statistically significant differences in 30-day and 1-year overall and 1-year cardiovascular mortality. CONCLUSIONS: Urgent MitraClip repairs can be performed successfully, when needed, in critically ill patients with severe MR. Despite the procedural success, patients undergoing urgent MitraClip repair remain at high risk for adverse outcomes in the short- and intermediate-term and incur increased cardiovascular mortality and morbidity. Further efforts are required to develop strategies to optimize short and intermediate outcomes in this vulnerable group of patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos Retrospectivos , Resultado do Tratamento
6.
BMC Anesthesiol ; 21(1): 137, 2021 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-33957865

RESUMO

BACKGROUND: Thoracic epidural analgesia has long been a common method of postoperative analgesia for major open abdominal surgeries and is frequently used within enhanced recovery after surgery programs. An alternative postoperative analgesia method is the single shot transversus abdominis plane block, which has shown promising outcomes with respect to total length of stay, cost, pain scores, and decreased opioid usage. However, far less is known regarding continuous transversus abdominis plane analgesia using catheters. We evaluated the total cost-effectiveness of transversus abdominis plane catheter analgesia compared to thoracic epidural analgesia for patients undergoing open colorectal surgeries within the enhanced recovery after surgery program at our institution. METHODS: This cohort study included patients booked under the colorectal surgery enhanced recovery after surgery program from November 2016 through March 2018 who received either bilateral transversus abdominis plane catheters (n = 52) or thoracic epidural analgesia (n = 24). RESULTS: There was no difference in total direct cost (p = 0.660) and indirect cost (p = 0.220), and median length of stay (p = 0.664) in the transversus abdominis plane catheter group compared to the thoracic epidural group. Additionally, the transversus abdominis plane catheter group received significantly less morphine equivalents compared to the thoracic epidural group (p = 0.008) and had a lower mean body mass index (p = 0.019). There was no significant difference between the two groups for age (p = 0.820), or sex (p = 0.330). CONCLUSIONS: Transversus abdominis plane catheter analgesia is not associated with increased cost or longer hospital stays when compared to thoracic epidural analgesia in patients undergoing open colorectal surgery within an enhanced recovery after surgery program. Furthermore, transversus abdominis plane catheter analgesia led to decreased opioid consumption while maintaining similar pain scores, suggesting similar pain control between the two modalities.


Assuntos
Analgesia Epidural , Catéteres , Colo/cirurgia , Bloqueio Nervoso/instrumentação , Reto/cirurgia , Músculos Abdominais , Analgesia Epidural/economia , Catéteres/economia , Estudos de Coortes , Recuperação Pós-Cirúrgica Melhorada , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/economia , Escala Visual Analógica
7.
J Cardiothorac Vasc Anesth ; 35(6): 1760-1768, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32980257

RESUMO

OBJECTIVE: Compare general anesthesia with a supraglottic airway versus monitored anesthesia care for transfemoral transcatheter aortic valve replacement (TF-TAVR) in patients with aortic stenosis. The authors hypothesized that the supraglottic airway group would have similar operating room and procedure times, postanesthesia care unit (PACU) and hospital stays, and similar rates of intraprocedural and postprocedural complications compared with the monitored anesthesia care group. STUDY DESIGN: Retrospective chart review with 1:1 propensity score matching of supraglottic airway to monitored anesthesia care patients. SETTING: Tertiary care academic medical center. PARTICIPANTS: TF-TAVR patients between 2017 and 2019. INTERVENTIONS: Supraglottic airway or monitored anesthesia care. MEASUREMENTS AND MAIN RESULTS: One hundred forty-eight supraglottic airway patients were matched with 148 monitored anesthesia care patients. Monitored anesthesia care patients had slightly shorter operating room (p < 0.001) and procedure times (p = 0.015). No difference was observed in hospital length of stay (p = 0.34). Fewer patients in the supraglottic airway group required a PACU stay >2 hours (p < 0.001). Use of intraprocedural vasopressors (p < 0.001) and fentanyl dosage (p < 0.001) was higher in the supraglottic airway group. No differences were observed in postoperative complications or procedural success rates. CONCLUSIONS: In this, the first study to compare these 2 modalities, supraglottic airway use was demonstrated to be a safe, feasible alternative to monitored anesthesia care during TF-TAVR and did not increase organ-specific morbidity, 30-day mortality, hospital length of stay, or PACU length of stay. Even though supraglottic airway was associated with slight increases in procedure and operating room times, these were not clinically significant.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Turk J Anaesthesiol Reanim ; 48(6): 491-496, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33313589

RESUMO

OBJECTIVE: Surgical aortic valve replacement requires a comprehensive transoesophageal echocardiography (TEE) assessment before and after the intervention by cardiac anaesthesiologists. For patients undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI), TEE is not routinely used. We started using transthoracic echocardiography (TTE) as a diagnostic and monitoring modality during TF-TAVI procedures. The aim of this study is to examine the usefulness of TTE before and after TF-TAVI. We hypothesised that TTE can serve as a screening tool in TF-TAVI patients and help rule out significant paravalvular leaks (PVLs), and serve as a monitoring tool. METHODS: A retrospective, observational study of 24 patients who underwent TF-TAVI with perioperative TTE over a 3-month period was conducted. Intraoperatively, two TTE examinations were performed. The first was a baseline pre-procedural TTE examination after anaesthetic induction, and the second was performed after TAVI valve implantation. Both pre- and post-procedural examinations included five focused TTE views. PVLs were graded as none, non-significant (trace or mild) or significant (moderate or severe). RESULTS: The average age and median body mass index of the patients were 82 years and 28.5 kg m-2, respectively. The average time recorded for the pre- and post-TAVI TTE examinations were approximately 4 and 5.5 min, respectively. Non-significant PVL was detected in 6 (25%) patients, and no leak was detected in 18 (75%) patients. CONCLUSION: A focused TTE examination was found to be a useful adjunct during TF-TAVI for a cardiac anaesthesiologist in the absence of TEE, and useful in ruling out significant PVLs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...